| REFERANS | FRBTIFR-BTI-2023-03138 |
|---|---|
| TÜR | AB BTB |
| GTİP | 8537.10.98 |
| KISA TANIM | Robot durdurma sistemli giriş kapısı. |
| TANIM | OTOMATIK BIR SISTEMDE INSAN GIRIŞ KAPISININ GÜVENLIĞINI SAĞLAMAK IÇIN EKIPMAN SETI (ÖRGÜ ÇITLE SINIRLANDIRILMIŞ LOJISTIK MUHAFAZA). KAPININ AÇILMASI, BIR ADAMIN IÇERI GIREBILMESI IÇIN ORADAKI ROBOTLARI DURDURAN GÜVENLIK SISTEMINI TETIKLER. KURULUM, KILITLEME SOLENOIDINE BAĞLI BIR TUTAMAĞA SAHIP BIR MANDAL, ERIŞIM KAPISI IÇIN BIR ANAHTAR ANAHTARI, BIR IŞIK (SIREN FLAŞI) VE SESLI (ZIL) ALARM CIHAZI, 'SISTEMIN KONTROL EDILMESINE VE KONTROL EDILMESINE OLANAK TANIYAN BIR KULLANICI ARAYÜZÜ'NDEN OLUŞUR. KESILMIŞ, SENSÖRLERE BAĞLI VE BIR ELEKTRIK KUTUSU IÇINDE BASMALI BUTONLAR (ACIL DURDURMA, SISTEMI SIFIRLAMA, ROBOTLARI AÇMA VE KAPATMA), FARKLI ELEMANLARI BIRBIRINE BAĞLAYAN KABLOLAR VE KONEKTÖRLER, KAPIYA ILIŞTIRILMIŞ BIR IŞARET (GÜVENLIK ÖNLEMLERI). ENERJI SÜREKLI BIR GÜÇ KAYNAĞI (24 V, 1,5 A) ILE SAĞLANIR. KURULUM ŞU ŞEKILDE ÇALIŞIR: SISTEME BAŞLANGIÇTA ENERJI VERILIR; 1) ANAHTARA TAKILAN ANAHTAR 0 KONUMUNA ÇEVRILIR, BIR PLC GIRIŞI ETKINLEŞTIRILIR VE SISTEMIN GÜVENLI OLMAYAN MODA GEÇMESI SAĞLANIR (5 V DÖNÜŞTÜRÜCÜ (ÇIKIŞ) ILE METRONOM ARASINDAKI GÜÇ KAYNAĞI, 2 RÖLE GÜVENLIĞI TARAFINDAN KESILIR VE SISTEMIN ÇALIŞMASI DURDURULUR) “SKYPODS” ROBOTLARI (“ASTAR” SINYALI); BIR DIZI ELEKTRONIK KARTTAN OLUŞAN METRONOM, HER ROBOTLA ILETIŞIM KURAR VE ONLARI YÖNETIR; 2) ROBOTLARIN DURDURULMASINI KONTROL ETMEK IÇIN 10 SANIYELIK BIR ZAMAN GECIKMESI BAŞLATILIR; 3) MAKINE, KOLUN KILIDINI AÇAR (NORMALDE KILITLIDIR, UYGUN ANAHTAR OLMADAN VE MÜHRÜ KIRMADAN DIŞARIDAN AÇILMASI IMKANSIZDIR) AÇMAYA IZIN VERIR; KIŞI MUHAFAZAYA GIREBILIR (IÇERIDE BIR KIŞI VARKEN YENIDEN BAŞLAMAYI ÖNLEMEK IÇIN ÜZERLERINDE ANAHTAR VARKEN). AYRILIRKEN, 1) KIŞI MUHAFAZADA KIMSENIN OLMADIĞINI KONTROL EDER, 2) ANAHTARI YUVASINA GERI YERLEŞTIRIR, 3) ONU 1 KONUMUNA ÇEVIRIR (SISTEM "GÜVENLI" ISE ARAYÜZDEKI SIFIRLAMA DÜĞMESI YANIP SÖNER) " (MODÜLLERDEN VEYA PLC'LERDEN HIÇBIR DEVRE KESICI, HÜCRE VEYA GÜVENLIK SINYALI ETKINLEŞTIRILMEZ)), 4) MAVI SIFIRLAMA DÜĞMESINE BASILDIĞINDA, SISTEMIN VE ROBOTLARIN YENIDEN BAŞLATILMASINA ILIŞKIN 10 SANIYELIK SESLI VE IŞIKLI SINYAL UYARISI ETKINLEŞTIRILIR; 5) 10 SANIYE SONRA, HERHANGI BIR GÜVENLIK DEVRE KESICISI ETKINLEŞTIRILMEZSE, OTOMAT GÜVENLIK RÖLELERINI KONTROL EDER, BÖYLECE METRONOMA GÜÇ VERIR: "ASTAR" HATASI ORTAYA ÇIKAR, ROBOTLAR GÖREVLERINE DEVAM EDER, SISTEM NORMAL ÇALIŞIR. |
| BAŞLANGIÇ TARİHİ | 12.05.2023 |
| BİTİŞ TARİHİ | 11.05.2026 |
| YABANCI TANIM | ENSEMBLE D’ÉQUIPEMENTS PERMETTANT D'ASSURER LA SÉCURITÉ DE LA PORTE D'ENTRÉE DE L'HOMME DANS UN SYSTÈME AUTOMATISÉ (ENCEINTE LOGISTIQUE, DÉLIMITÉE PAR UNE CLÔTURE GRILLAGÉE). L'OUVERTURE DE LA PORTE DÉCLENCHE LE SYSTÈME DE SÉCURITÉ QUI Y ARRÊTE LES ROBOTS AFIN QU’UN HOMME PUISSE Y ENTRER. L’INSTALLATION SE COMPOSE D’UNE CLENCHE AVEC UNE POIGNÉE COUPLÉE À UN SOLÉNOÏDE DE VERROUILLAGE, D’UN INTERRUPTEUR À CLÉ POUR PORTE D’ACCÈS, D’UN DISPOSITIF D’ALARMES LUMINEUX (SIREN FLASH) ET SONORE (BUZZER), D’UNE INTERFACE-UTILISATEUR DE CONTRÔLE ET COMMANDE DU SYSTÈME PERMETTANT LA COUPURE DE CELUI-CI, RELIÉE À DES CAPTEURS ET MUNIE DE BOUTONS POUSSOIRS (ARRÊT D’URGENCE, RÉARMER LE SYSTÈME, ALLUMER ET ÉTEINDRE LES ROBOTS) À L’INTÉRIEUR D’UN COFFRET ÉLECTRIQUE, DE CÂBLES ET CONNECTIQUES RELIANT LES DIFFÉRENTS ÉLÉMENTS, D’UN PANNEAU SIGNALÉTIQUE (MESURES DE SÉCURITÉ) FIXÉ SUR LA PORTE. L’ÉNERGIE EST FOURNIE PAR UNE ALIMENTATION ÉLECTRIQUE CONTINUE (24 V, 1,5 A). L’INSTALLATION FONCTIONNE AINSI: SYSTÈME SOUS TENSION INITIALEMENT; 1) LA CLÉ INSÉRÉE DANS L’INTERRUPTEUR EST TOURNÉE EN POSITION 0, ACTIVANT UNE ENTRÉE AUTOMATE FAISANT PASSER LE SYSTÈME EN MODE NON "SAFE" (L’ALIMENTATION ENTRE LE CONVERTISSEUR 5 V (SORTIE) ET UN MÉTRONOME EST COUPÉ PAR 2 RELAIS DE SÉCURITÉ STOPPANT LES ROBOTS "SKYPODS" (SIGNAL "ASTAR"); LE MÉTRONOME, ENSEMBLE DE CARTES ÉLECTRONIQUES, COMMUNIQUE AVEC CHAQUE ROBOT ET LES GÈRE); 2) UNE TEMPORISATION DE 10 S EST LANCÉE POUR CONTRÔLER L’ARRÊT DES ROBOTS; 3) L’AUTOMATE DÉVERROUILLE LA POIGNÉE (NORMALEMENT VERROUILLÉE, IMPOSSIBLE À OUVRIR DE L’EXTÉRIEUR SANS LA CLÉ ADÉQUATE ET BRISER LE SCEAU) AUTORISANT L’OUVERTURE; LA PERSONNE PEUT ENTRER (AVEC LA CLÉ SUR SOI POUR ÉVITER UN REDÉMARRAGE AVEC UNE PERSONNE À L’INTÉRIEUR) DANS L’ENCEINTE. EN SORTANT, 1) LA PERSONNE VÉRIFIE L’ABSENCE DE QUICONQUE DANS L’ENCEINTE, 2) REPLACE LA CLÉ DANS SON LOGEMENT, 3) LA TOURNE EN POSITION 1 (LE BOUTON DE RÉARMEMENT SUR L’INTERFACE CLIGNOTE SI LE SYSTÈME EST "SAFE" (AUCUN DISJONCTEUR, NI CELLULES OU SIGNAUX DE SÉCURITÉ ACTIVÉS DE MODULES OU D’AUTOMATES)), 4) APPUIE SUR LE BOUTON DE RÉARMEMENT BLEU, ACTIVANT AINSI UN SIGNAL SONORE ET LUMINEUX DE 10 S PRÉVENANT DU REDÉMARRAGE DU SYSTÈME ET DES ROBOTS; 5) APRÈS LES 10 S, SI AUCUN DISJONCTEUR DE SÉCURITÉ N’EST ACTIVÉ, L’AUTOMATE COMMANDE LES RELAIS DE SÉCURITÉ, ALIMENTANT AINSI LE MÉTRONOME: L’ERREUR "ASTAR" EST LEVÉE, LES ROBOTS REPRENNENT LEURS MISSIONS, LE SYSTÈME SON FONCTIONNEMENT NORMAL. |
Otomatik gümrük beyanname kontrolü |
Yapay zeka ile fatura okuma |
Yapay zeka ile gtip tahmini |
Gümrük müşavir programı |
Yapay zeka ile gtip tahmini |
Gümrük müşavir portalı |
Gümrük beyanname takip sistemi |
Gümrük ceza takip sistemi |
Email takip sistemi |
İthal ürün takip sistemi |
İhracat fatura takip sistemi |
Muhasebe denetim sistemi |
Sonradan kontrol sistemi |
Telafi edici vergi hesaplama