İzahname 40.sayfa

GTİP veya BTB arama formu

Arama sonuç listesi (16.704 adet)

Bilgi Tanım Resim
İZAHNAME


9027
(II) YANMA VEYA PATLAMA ALETLERI. BUNLAR ILAVETEN, YANMA VEYA PATLAMA PIPETI (PLATIN ÇOK INCE TÜPÜ, PLATIN VEYA PALLADYUM TEL: TÜPÜ, INDEKSIYON KIVILCIMLAYICISIYLA BERABER, VB.) ILE TEÇHIZ EDILMIŞTIR.
İZAHNAME


9027
(I) ORSAT ALETI, BAŞLICA OLARAK BIR EMICI, BIR YA DA DAHA FAZLA EMICI BALON VE ÖLÇÜCÜ CAM TÜPTEN OLUŞUR.
İZAHNAME


9027
(8) GAZ VEYA DUMAN ANALIZLERINE MAHSUS CIHAZLAR. BUNLAR, GAZ HALINDEKI YAKITLARLA, KOK FIRINLARINDA, GAZOJENLERDE, YÜKSEK IZABE FIRINLARINDA, VB. DE YANMADAN HASIL OLAN TALI ÜRÜNLERIN (YANMIŞ GAZLARIN) ANALIZLERINDE KULLANILMAKTA VE BU SURETLE BILHASSA IMALATIN RASYONEL BIR ŞEKILDE YAPILABILMESINI TEMIN BAKIMINDAN BU GAZLARIN TERKIPLERINDE BULUNAN KARBON DIOKSIT, KARBON MONOKSIT, OKSIJEN, HIDROJEN, AZOT VEYA HIDROKARBÜRLERIN DOZLANDIRILMASI IMKANI SAĞLANMAKTADIR. ELEKTRIKLI GAZ VE DUMAN ALETLERI BAŞLICA OLARAK AŞAĞIDAKI, GAZLARIN MUHTEVIYATINI BELIRLEMEYE VE ÖLÇMEYE MAHSUSTUR: KARBONDIOKSIT, KARBON MONOKSIT VE OKSIJEN, HIDROJEN, KÜKÜRT DIOKSIT, AMONYAK.
İZAHNAME


9027
BU GRUP, OPTIK ANALIZLERE AIT DIĞER CIHAZLARI, ÖRNEĞIN, NEFELOMETRELERI VE TÜRBIDIMETRELERI (KARIŞIMLARIN BULANIKLIK DERECESINI TAYINE MAHSUS); ABSORPSIYOMETRELERI VE FLÜOROMETRELERI (FLÜORESANSIN TAYINI ESASINA DAYANAN BU CIHAZLAR VITAMINLERIN, ALKOITLERIN, VB. ANALIZINDE KULLANILMAKTADIR); BLONŞIMETRELERI VE OPASIMETRELERI (BILHASSA KAĞIT HAMURU, KAĞIT VB. BEYAZLIĞINI, DONUKLUĞUNU VE PARLAKLIĞINI ÖLÇMEDE KULLANILIR), VB. DE IÇINE ALMAKTADIR.
İZAHNAME


9027
(7) KOLORIMETRELER."KOLORIMETRE" TABIRI, BIRBIRINDEN FARKLI IKI ALETI IFADE EDER. BUNLARDAN BIRI, KATI VEYA SIVI HALDEKI MADDELERIN RENGINI TAYIN AMACIYLA KULLANILMAKTADIR. BU ŞEKILDEKI RENK TAYINI, ÜÇ ANA RENGIN (KIRMIZI, YEŞIL, MAVI) ÖLÇÜLEBILECEK NISPETLERDE KARIŞTIRILMASINDAN MEYDANA GELEN RENKLERLE KARŞILAŞTIRILMASI SURETIYLE OLUR. DIĞER NEVI KOLORIMETRELER, KIMYA VE BIYOKIMYA TAHLILLERINDE BIR KARIŞIMIN IÇINDE BULUNAN HERHANGI BIR MADDENIN KONSANTRASYON DERECESININ TAYININDE KULLANILMAKTADIR. BU SURETLE KONSANTRASYON DERECESININ TAYINI, KARIŞIMIN IÇINDEKI MADDENIN RENGI (VEYA MADDENIN BIR AYIRAÇ ILE MUAMELE EDILDIKTEN SONRAKI RENGI) KIYAS TEŞKIL EDEN BIR SIVININ RENGI ILE KARŞILAŞTIRILMAK SURETIYLE OLUR. BU SONUNCU NEVIDEN OLAN KOLORIMETRENIN BIR TIPINDEKI, KONSANTRASYON DERECESI TAYIN OLUNACAK KARIŞIM ILE KIYAS TEŞKIL EDEN KARIŞIM IKI AYRI TÜP IÇERISINE KONULMAKTA VE HER IKISI BIR ARADA IKI PRIZMA VASITASIYLA BIR OKÜLERDEN BAKILARAK TETKIK OLUNMAKTADIR. BU ALETLERIN BAZILARI FOTOELEKTRIK HÜCRE KULLANIMI ESASINA DAYANIR, KAĞIT ŞERIT, GAZLI TEPKIMEDEN SONRA RENGINI DEĞIŞTIREN BIR MIYARLA KULLANILIR. BU TÜR CIHAZLARIN BAZILARINDA KAĞIT ŞERIT GAZLA TEPKIMEYE GIRDIKTEN SONRA RENK DEĞIŞTIREN BIR AYRAÇLA KULLANILIR. BU ALETLER GAZLA TEPKIMEDEN ÖNCE VE SONRA RENGI ÖLÇECEK IKI FOTOELEKTRIK HÜCRE KULLANIR.
İZAHNAME


9027
(6) MADDELERIN IZOTOPIK BILEŞIMLERINI VB. ANALIZ EDEN MASS (KÜTLE) SPEKTROSKOPLARI VE BENZER CIHAZLAR. FAKAT BU POZISYON IZOTOPIK AYRILMA IÇIN OLAN KALUTRONLARI IÇERMEZ (84.01 POZISYONU).
İZAHNAME


9027
BU POZISYON HÜZMELERIN GÖZLEMLENMESINE MAHSUS SPEKTROSKOPLARI; HÜZMENIN BIR FOTOĞRAF LEVHA VE FILMI ÜZERINE TESBITINE VE BÖYLECE SPEKTOGRAMLARININ ELDE EDILMESINE MAHSUS SPEKTOGRAFLAR; DOĞRUSAL BIR HÜZMENIN IÇINDEKI BELLI BIR HATTI VEYA SÜREKLI BIR HÜZMENIN BELLI BÖLÜMLERINI IZOLE ETMEYE MAHSUS MONOKROMATÖRLERI IÇINE ALIR.
İZAHNAME


9027
(5) SPEKTROMETRELER. BUNLAR, EMISYON VE SOĞURMA HÜZMELERININ DALGA BOYUNU ÖLÇMEYE MAHSUS CIHAZLAR OLUP, ESAS ITIBARIYLA AYARLANABILIR NEVIDEN YARIĞI BULUNAN BIR KOLIMATÖR (IÇINDEN ANALIZI YAPILACAK IŞIK HUZMESI GEÇMEKTEDIR), BIR VEYA DAHA ÇOK AYARLANABILIR PRIZMA, BIR GÖZLEME DÜRBÜNÜ VE BIR DE PRIZMA TABLASINDAN MÜTEŞEKKILDIR. BAZI SPEKTROMETRELERDE (BILHASSA, KIZIL ÖTESI VEYA ULTRAVIYOLE IŞINLARI IÇIN KULLANILANLARDA) PRIZMALAR BULUNMAKTA VE BAZI HALLERDE DE DIFRAKSIYON IZGARALARI KULLANILMAKTADIR.
İZAHNAME


9027
(4) REFRAKTOMETRELER. BUNLAR, SIVI VE KATI MADDELERIN (BUNLARA ÇARPAN IŞIN KIRILMA KATSAYISINI) TAYININE MAHSUS CIHAZLARDIR. MADDELERIN SAFLIĞININ TAYININDE KIRILMA INDISI EN MÜHIM UNSURLARDAN BIRINI TEŞKIL EDER. BUNLARDA ESAS OLARAK PRIZMALARDAN MÜTEŞEKKIL BIR TERTIBAT ILE GÖZLEME VE OKUMA GÖZLERI VE BIR DE SICAKLIK KONTROLÜNE MAHSUS TERTIBAT (SICAKLIĞIN KIRILMA KATSAYISINA OLAN FAZLA TESIRI DOLAYISIYLA) BULUNMAKTADIR. BU CIHAZLARIN TATBIK SAHASI ÇOK GENIŞ OLUP, BILHASSA GIDA SANAYIINDE (SIVI YAĞLARIN, TEREYAĞININ VE DIĞER YAĞLI MADDELERIN TEST EDILMESINDE, REÇELLERIN VE MEYVE SULARININ ANALIZINDE VB.) CAM SANAYINDE, PETROL RAFINERILERINDE VE BIYOLOJIDE (KAN SERUMUNUN VE DIĞER AKICI MADDELERIN IÇINDEKI PROTEIN MIKTARININ TAYININDE, VB.) KULLANILMAKTADIR. REFRAKTOMETRELERIN ÇOĞU BIR KAIDE VEYA SEHPA ÜZERINE MONTE EDILMIŞ VAZIYETTEDIR. BAZILARI ELDE KULLANILAN TIPTE VE DIĞER BAZILARI DA IMALAT KÜV VE SARNIÇLARININ CIDARLARINA TESBIT EDILECEK ŞEKILDEDIR.
İZAHNAME


9027
(3) SAKARIMETRELER. BUNLAR, ŞEKER ÇÖZELTILERININ ŞEKER ORANINI BELIRLEMEK IÇIN DÜZENLENEN ÖZEL POLARIMETRELERDIR.
İZAHNAME


9027
(2) YARI GÖLGELI POLARIMETRELER. DÜZLEM VEYA ELIPS ŞEKLINDE POLARIZE IŞIĞI ANALIZ ETMEK IÇINDIR.
İZAHNAME


9027
(1) POLARIMETRELER. OPTIK OLARAK AKTIF BIR MADDEDEN GEÇERKEN, IŞIK IŞINININ POLARIZASYON DÜZLEMINDEKI ROTOSYON AÇISINI ÖLÇEN CIHAZLARDIR. ESASEN BIR IŞIK KAYNAĞI, POLARLAYICI VE ANALIZÖR PRIZMALARDAN OLUŞAN OPTIK ALET, ANALIZ EDILECEK MADDENIN KONDUĞU TÜP, GÖZLEMLEME GÖZLERI VE ÖLÇÜM TAMBURASINDAN OLUŞUR. ELEKTRONIK POLARIMETRELER, SIRADAN POLARIMETRENIN GEREKLI ÖĞELERINE ILAVETEN FOTOELEKTRIK HÜCRE (FOTOSEL) DE IÇERIR.
İZAHNAME


9027
MIKROTOMLAR; AKSAM, PARÇA VE AKSESUAR
İZAHNAME


9027
KÜTLE SPEKTROMETRELERI
İZAHNAME


9027
OPTIK IŞINLI (UV, GÖRÜLEBILIR IŞINLAR, IR) SPEKTROMETRELER, SPEKTROFOTOMETRELER VE SPEKTROGRAFLAR
İZAHNAME


9027
KROMATOGRAFLAR VE ELEKTROFOREZ CIHAZLARI
İZAHNAME


9027
GAZ VEYA DUMAN ANALIZ CIHAZLARI
İZAHNAME


9027
FIZIKSEL VEYA KIMYASAL ANALIZ IÇIN ALET VE CIHAZLAR (POLARIMETRELER, REFRAKTOMETRELER, SPEKTROMETRELER, GAZ VEYA DUMAN TAHLIL CIHAZLARI); AKIŞKANLIĞI, GÖZENEKLILIĞI, GENLEŞMEYI, YÜZEY GERILIMINI, VEYA BENZERLERINI ÖLÇMEYE VEYA MUAYENEYE MAHSUS ALET VE CIHAZLAR; ISI, IŞIK VE SES ÖLÇMEYE VEYA MUAYENEYE MAHSUS ALET VE CIHAZLAR (POZOMETRELER DAHIL); MIKROTOMLAR.
İZAHNAME


7017
ŞU KADAR KI, 70.17 POZISYONU ANLAMINDA YANDAN BASINÇ LABORATUAR EŞYASI MAHIYETINDE OLANLAR BU POZISYON HARICINDEDIR.
İZAHNAME


9032
BUNUNLA BERABER, MUAYYEN BIR KALORIFIK GÜÇTE KARIŞIM GAZ ELDE EDILMESI MAKSADIYLA BIR REGÜLATÖR TERTIBATIYLA BIRLEŞTIRILMIŞ HALDE BULUNAN KALORIMETRELER BU POZISYON DIŞINDA KALIR (90.32 POZISYONU).
İZAHNAME


8531
SADECE ALARMA DONATILMIŞ ELEKTRONIK DUMAN DEDEKTÖRLERI 85.31 POZISYONUNA GIRER.
İZAHNAME


7017
FAKAT SADECE LABORATUAR CAM EŞYALARINDAN OLUŞAN GAZ ANALIZ CIHAZLARI 70.17 POZISYONUNDADIRLAR.
İZAHNAME


9030
ELEKTRIKSEL DEĞIŞKENLERI ÖLÇMEK YA DA KONTROL ETMEK IÇIN SPEKTRUM ANALIZLERINI (90.30 POZISYONU)
İZAHNAME


9011
SPEKTOGRAMLARIN OPTIK MÜŞAHEDE SURETIYLE MUKAYESELI BIR ŞEKILDE TETKIKINE MAHSUS MIKROMETRIK MIKROSKOPLAR VE MIKROSKOPLU SPEKTROKOMPARATÖRLER (90.11 POZISYONU)
İZAHNAME


9008
SPEKTROGRAMLARIN BÜYÜTÜLMÜŞ OLARAK BIR EKRAN ÜZERINDE GÖRÜLMESINI TEMINE MAHSUS SPEKTROPROJEKTÖRLER (90.08 POZISYONU);
İZAHNAME


9005
GÜNEŞIN GÖZLEMLENMESINDE KULLANILAN SPEKTROHELYOGRAFLAR VE SPEKTROHELYOSKOPLAR (90.05 POZISYONU);
İZAHNAME


9026
BU BÖLÜMDE NOT 1 VE 2 DEKI NOT HÜKÜMLERI SAKLI KALMAK KAYDIYLA (GENEL AÇIKLAMA NOTUNA BAKINIZ) BU POZISYONA GIREN ALET VE CIHAZLARIN AYRI GELEN AKSAM, PARÇA VE AKSESUARI BURADA SINIFLANDIRILMIŞTIR. ÖRNEĞIN, SINYALLER, ÖN SEÇIM VEYA KONTROL EDICI ALETLERLE BIRLEŞSIN VEYA BIRLEŞMESIN, AYRI OLARAK BULUNAN GRAFIK KAYDEDICI CIHAZLARI (ÇOK SAYIDA ÖLÇÜCÜ VEYA KONTROL EDICI ALETLER TARAFINDAN SAĞLANAN GÖSTERILMELERIN KAYIT EDILDIĞI ALETLER DAHIL)
İZAHNAME


9026
(IV) KALORIMETRELER KALORIMETRELER BIR TERTIBATTAKI (ÖRNEĞIN, SICAK SU TIPI ISITMA SISTEMINDE) YANAN (TÜKETILEN) ISI MIKTARINI ÖLÇER. BUNLAR ESASEN YA SIVI TEDARIK SAYAÇLARINDAN VEYA KANALIN GIRIŞINE VE ÇIKIŞINA YERLEŞTIRILMIŞ IKI TERMOMETREDEN YA DA SAYICI VE TOPLAYICI MEKANIZMALARDAN OLUŞUR. BU GRUP THERMOCOUPLE KALORIMETRELERI DE IÇINE ALIR.BINA KATLARINDA GENEL ISITMA BEDELININ GEREĞI GIBI BÖLÜNMESINI SAĞLAYAN VE KATLARIN RADYATÖRLERINE MONTE EDILEN KÜÇÜK TIP KALORIMETRELER, TERMOMETRELERE BENZER VE SICAKLIĞIN ETKISI ALTINDA BUHARLAŞAN BIR SIVI IÇERIR.
İZAHNAME


9026
POZISYON MAKSIMUM VE MINIMUM TIP BASINÇ GÖSTERGELERINI DE IÇINE ALIR. DIFRANSIYEL BASINÇ GÖSTERGELERI BASINÇTAKI DEĞIŞIKLIKLERI ÖLÇMEDE KULLANILIR. BUNLARIN AŞAĞIDAKI ÇEŞITLERI VARDIR: ÇIFT SIVI DUBA, SALINAN HALKA TERAZISI, DIYAFRAM KAPSÜL, KÜRE (SIVISIZ) VB.
İZAHNAME


9026
VAKUM GÖSTERGELERI ÇOK DÜŞÜK BASINÇLARI ÖLÇMEK IÇINDIR. TERMIYONIK (SICAKLIKTAN AKIM DOĞURAN) VAKUM TÜPLERINI (TRIADLARI) KULLANAN IYONIZASYON GÖSTERGELIDIR. BUNLARDAN ARTIK GAZ MOLEKÜLLÜ ELEKTRONLARIN ÇARPIŞMASI SONUCU ÜRETILEN POZITIF IYONLAR, NEGATIF TABAKAYA DOĞRU ÇEKILIR. AYRI OLARAK BULUNAN TERMIYONIK VAKUM TÜPLERI (TRIADLAR) AYRI OLARAK GELDIKLERINDE (85.40 POZISYONU) DADIR.
↑ Başa dön
Otomatik gümrük beyanname kontrolü | Yapay zeka ile fatura okuma | Yapay zeka ile gtip tahmini | Gümrük müşavir programı | Yapay zeka ile gtip tahmini | Gümrük müşavir portalı | Gümrük beyanname takip sistemi | Gümrük ceza takip sistemi | Email takip sistemi | İthal ürün takip sistemi | İhracat fatura takip sistemi | Muhasebe denetim sistemi | Sonradan kontrol sistemi | Telafi edici vergi hesaplama